Manual Deye Smart Meter Single Phase
Manual Deye Smart Meter Three Phase
Single-phase electronic energy meters mounted on guide rail SDM120CT PLUS. It is used to monitor and display the grid power (voltage, current frequency and power) and transfer this information to the solar inverter via RS485 communication in a zero export system. The SDM120CT PLUS series (din rail) three phase electronic energy meter is designed based on the demands of monitoring and measuring energy for photovoltaic plants, etc. It is mainly applied in the measurement and display of grid parameters in zero export system, including grid voltage, current, active power, reactive power, frequency, etc.
Installation
The installation of this battery model is very simple, however, at Wccsolar we recommend that you sea installed by a photovoltaic professional, or the installation instructions are strictly followed to avoid bad connections and breakdowns due to incorrect installation.
Buy PlusEnergy
To buyit is fast, safe and comfortable thanks to Wccsolar, in addition It has an official Wccsolar guarantee.
Contact us to receive more information.
Deye Smart meter Single Phase / Three Phase Meter Sensor
Technical Specifications DDSU666-H
General specifications
Dimensions (height x width x depth) 100 x 36 x 65.5 mm
Mounting type DIN35 rail
Weight (including cables) 1.2 kg
Power supply
Type of electrical network 1P2W
Input power (phase voltage) 176 VAC ~ 288 VAC
Power consumption ≤ 0.8W
Measuring range
line voltage /
Phase voltage 176 VAC ~ 288 VAC
Current 0~100A
Measurement accuracy
Voltage ±0.5%
Current / Power / Energy ±1%
Frequency ±0.01Hz
Communication
RS485 interface
Baud rate 9600 bps
Communication protocol Modbus - RTU
Environment
Operating temperature range -25 °C ~ 60 °C
Storage temperature range -40 °C ~ 70 °C
Operating humidity 5% RH ~ 95% RH (non-condensing)Solarman Business App
This web page is installed APP solarman
https://download.solarmanpv.com/qrdownload/index.html?target=bEastron SDM630MCT Three Phase
Max. continuous current measurement (A) 1-9999A (with CT)
Continuous voltage measurement between phases 50-950V // 50-550V
Direct measurement between phase and neutral 20-550V
Active power Class 1
Reactive power Class 2
Electrical consumption ≤2W/10VA
AC power supply input voltage 85-275V/120-380V
AC power supply input frequency 50/60Hz ±2%
Dimensions (mm) 72×94.5×65
Weight (Kg) 0, 29
Mounting options Din rail
IP protection class IP51
Display LCD
Communication interface RS485
Max. number of devices to connect 32
Regulated working temperature range -25ºC ~ +55ºC
Humidity 0-95% non-condensing