Know your Solar installation
top of page

Know your Solar installation

Updated: Oct 9, 2023

In this section we collect 11 solar tips so you can learn about the characteristics and peculiarities of a solar installation. Carry out a correct dimensioning of it and make the most of the advantages offered by solar energy. Let us begin...



Distribución de un sistema de Instalación Solar
Distribution of a Solar Installation system


Tip 1


INSTALLATION IN DIRECT CURRENT (12v) OR IN ALTERNATING CURRENT (220v): Did you know..? Before starting to dimension an installation, it will be important to determine the use that we are going to give it. If it is a home or shelter where we only want to install lighting and where there is little wiring route, the installation can be done at 12v so it will not be necessary to install a power inverter. In this case, the low consumption bulbs to be used will be 12v. If, on the other hand, additional use of conventional electrical appliances in your home is required, such as TV, appliances, refrigerator, etc., or long-distance light installations, a power inverter from 12v (direct current) to 220v (current current) will be used. alternate).


Tip 2


CHOOSE THE REGULATOR ACCORDING TO THE INSTALLED PANEL POWER: Did you know..? To correctly choose the power of the regulator, it will be necessary to see the technical sheet of the panel or panels that make up the installation. The short-circuit current (data indicated as ISC) will be taken as the value. If the installation only has a panel whose ISC = 8.2 Amps, a 10A regulator will be necessary. If you have several panels, this value will be multiplied by the number of connected panels. That is, if you have 4 130W panels, the total ISC will be 32.8 amps, so a 40A solar regulator will be necessary.


Tip 3


THE INCLINATION OF THE PANELS ACCORDING TO THEIR SEASON OF USE: Did you know..? During an installation, it is important to determine the degree of inclination of the solar panels. This will depend on the use we want to give to the installation: If we want constant use throughout the year, the ideal is to give the panel an inclination equal to the latitude of the place plus 18º, the same as the one we would put if the installation was only for winter use. This is done as it is the most suitable inclination for winter, when there is less solar intensity and it is necessary to maximize it. On the other hand, in summer, it is advisable to place the panels at an angle of inclination equal to the latitude of the place minus 18º.


Tip 4


THE USE OF AN INVERTER - CHARGER IN A SOLAR INSTALLATION: Did you know..? For installations where a high consumption of electricity is required at a specific time, it is recommended to have an external source of support such as a generator set. When it is used, the part of the energy that is not consumed will be used by the charger to charge the batteries of the installation, improving the availability of energy for any other use. The fact that there is an inverter-charger allows to have both functions in the same device, power inverter from 12 or 24V to 220V and battery charger. It is important to choose the appropriate model for the power of the installation.


Tip 5


THE IMPORTANCE OF USING A PURE WAVE INVERTER: Did you know..? In installations that require the use of electrical appliances, a computer, a refrigerator, a TV or another type of electrical device, it is recommended to use a pure wave power inverter. These inverters generate a perfect current wave like the one you have in your home and that allows excellent operation of any 220V device. Modified sine wave inverters generate an electronically modified wave which can cause operating problems with complex electronic equipment, but will work well with other devices.


Tip 6


WIRING TO BE USED IN THE SOLAR INSTALLATION: Did you know..? The diameter of the wiring to be used in an installation will depend on the power of the installation as well as its voltage (12V or 220V). In the part of the installation that works at 12V and that goes from the solar panel to the regulator, wiring with a minimum diameter of 4mm2 will be used, depending on the power of the panels. In the rest of the installation, in the event that it works totally at 12V, wiring of at least this thickness will also be used. In the case of medium or high power installations, it will be necessary to operate at 220V (use of an inverter), which will allow the transport of a large amount of energy with a cable section of 1.5mm2, 2mm2 or up to 4mm2. It is recommended to determine the section of the cable in each section of the installation using this application: Calculate the cable section.


Tip 7


THE MOST DELICATE PART OF AN INSTALLATION, THE BATTERIES:

Did you know..? The battery is the most delicate element of a solar installation, and its correct dimensioning will greatly influence optimizing its useful life. For a solar installation it is essential to use deep cycle batteries, either of the monoblock, AGM, Gel or Stationary. These batteries allow large discharges, which makes them ideal for solar installations where significant and continuous consumption is required. Unlike these, conventional batteries such as those in automobiles allow only low percentages of discharge and their useful life is very short.


Tip 8


PUT A MONOBLOCK OR AGM SOLAR BATTERY?: Did you know..? If we carry out a small or medium-sized installation, monoblock solar batteries or AGM can be used. The use of one model or another will depend on whether we use appliances with a motor: refrigerator, refrigerator, washing machine, dishwasher or water pump. In this case, AGM batteries should be used since they withstand the starting peaks of these devices well without affecting the battery's useful life. In the event that other devices without a motor or very low power motors are used, such as a television, DVD, microwave, blender, lighting, computer, extractor, etc., the monoblock solar battery model can be used. It is very important to respect the use of each battery since incorrect use will make its useful life very short, which will affect the customer's pocket.


Tip 9


OPzS, TOPzS, UOPZS, OPZV AND MSP STATIONARY BATTERIES: Did you know..? For installations that require a large amount of accumulation in batteries, it is recommended to use the so-called stationary batteries. These batteries are formed by adding 6 2v glasses to get 12v of operation, and by adding 12 glasses to get 24v of operation. They have an extraordinarily low self-discharge level and a high deep discharge capacity.

Tip 10


MPPT TYPE REGULATORS AND THEIR USE: Did you know..? It will be necessary to use MPPT regulators when in our isolated solar installation we use solar panels connected to the grid, that is, 24v panels with power in watts equal to or greater than 200w. EI that are commonly used in solar farms. Unlike the 12v and 24v isolated panels that generate a voltage of 18v and 36v respectively, the grid connection panels generate a voltage very close to 24v, so adding the losses that occur in the transport of this current towards the batteries, it ends up reaching a voltage below 24v. This means that if a normal regulator is used, the battery cannot find the balance between the energy it accumulates at 24v and the energy that comes from said panels at a lower voltage. Which ends up causing irreparable damage to the battery. The MPPT regulator maximizes the voltage so that it reaches the batteries at a level similar to that of isolated panels, allowing its accumulation in the batteries optimally. An isolated 24v panel and a grid connection panel will differ in that the maximum voltage point (in the panel's technical sheet: Vmp) of the isolated panel will be similar to 36 Volts, while in a grid connection panel it will be only 29v or similar.


Tip 11


HOW TO KNOW THE CHARGE LEVEL OF A SOLAR BATTERY ACCORDING TO ITS VOLTAGE: Did you know..? A solar battery will indicate a certain voltage according to the charge level it is in at any given moment. This is very useful to know exactly your load percentage. For this, it is necessary to watch it at rest, that is, at least one hour after disconnecting the loads (either from the panels or from an external source such as a generator set). The ideal time is at night, when there is no longer any sun and when the plates do not generate electricity. This must be done since while the batteries receive current, their voltage will be distorted and not the real one. The following voltage/charge level relationship is suitable for all types of solar batteries, whether they are monoblock solar, AGM, Gel or stationary batteries:

BATTERY CHARGE LEVEL IN A 12v SOLAR INSTALLATION 100% battery (fully charged) = 12.7 V (volts) Battery at 75% = 12.5V 50% battery = 12.2V Battery at 30% = 12V Flat battery = 11.6V BATTERY CHARGE LEVEL IN A 24v SOLAR INSTALLATION 100% battery (fully charged) = 25.4V Battery at 75% = 25V 50% battery = 24.4V Battery at 30% = 24V Flat battery = 23.2V BATTERY CHARGE LEVEL IN A 48v SOLAR INSTALLATION 100% battery (fully charged) = 50.8V Battery at 75% = 50V 50% battery = 48.8V Battery at 30% = 48V Flat battery = 46.4V



Contact us to receive more information.

In WccSolar we are Multibrand Distributors of Solar Energy Supplies.

 

WccSolar is First Distributor of several brands of Solar Inverters, We also have an associated technical service to respond quickly to any problem or incident that could be caused by your Inverter devices.

 

This technical service will be active both during the warranty period and outside this period. In which this service will be offered to the client so that any problem can be solved. Offering peace of mind to the customer in the purchase of our devices.

TECHNICAL-SERVICE--en.jpg
Secure payment
ssl-secure-connection-2.jpg

Customer Service and Telephone Sales

854 556 349

Technical service

954 089 500

Send us your Queries

servicio@wccsolar.es

install wccsolar solar kit
free solar energy

Schedule

Monday to Friday

From 10:00 to 19:00

shipping to europe wccsolar

Shipments to Spain in 24h
In Europe

3-6 day

All our products for Renewable Energies comply with the most demanding regulations.

All our products for Renewable Energies comply with the most demanding regulations.

5PORCIENTO-1570548999.jpg
bottom of page